Hemodialysis Machine

  • Hemodialysis Machine
Hemodialysis Machine
  next

Hemodialysis Machine

  • Item No.:  KTC35-HM2028
  •  
  • inquiry
product detail make an inquery

KTC35-HM2028 Hemodialysis Machine main technical parameter

◆ Volume (length× width ×height):
    370mm×340mm ×1570mm
◆ Weight: about 90kg   
◆ Power supply voltage: AC220V±10%   
    Frequency: 50HZ ~ 60 HZ
    Power: 1500W
◆ Blood pump/spare pump:
    Flux: 15 ~ 340ml/min (Ф 6mm)
               20 ~ 460 ml/min (Ф 8mm)
◆ Heparin pump:
    Flux: 0.1ml/h~10ml/h(±5%)
    Precise: 0.1ml/h
    Injector size: 20ml/30ml/50ml
                            10ml/20ml/30ml
                            (selectable)
◆ Arterial pressure:
    display scope:-300mmHg~+300mmHg
                                                      (±10mmHg)
◆ Venous pressure:
    display scope:-50mmHg~+300mmHg
                                                    (±10mmHg)
◆ Dialysate flow:
   300ml/min~800ml/min linearity adjustable
                     (+10%)
                     (-5%)
   Temperature:35.0℃~39.0℃
   Resolving rate:0.1℃
   Conductivity:13mS/cm~15.5mS/cm
                         (±0.1 mS/cm)

◆ UF flow scope:                                  0~1800ml/h(±30ml/h )
0~4000ml/h(optional)

◆ ISO UF flow scope:                         0~2000ml/h(±30ml/h)

◆ TMP
    Scope:-100mmHg~+600mmHg
                                    (±20mmHg)

◆ Blood leakage monitor:
    over 1ml blood per liter dialysate
             (flow:500ml/min)

◆ Blood level monitor: ultrasonic sensor

◆ Air bubble monitor:
Infrared and response threshold value: Single air bubble of 200 и I exists when
Blood flux is 200ml/min

◆ Inflow pressure:0MPa~0.6MPa

◆ Inflow temperature: 5℃~30℃

◆ Environment temperature: 10℃~30℃,
Relative humidity≤70%

◆ Rinse/disinfection: chemical disinfection
(citric acid, peracetic acid and oxalic acid)

◆ Hot rinse: 80℃

◆ Back-up power supply: last for 15-30min after electric-cut.

KTC35-HM2028 function

Be applicable of hemodialysis treatment, hemoperfusion, Plasma Exchange, Pure ultrafiltration project.

Touch screen was equipped and it can show Naand UF profiles; In addition, the functions ie. backup power supply, Kt/V,HC adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect. are optional.

Clinical Application

◆ Hemodialysis Therapy: same as KTC-2000
◆ Pure ultrafiltration Therapy: same as KTC-2000
◆ Hemoperfusion Therapy: same as KTC-2000
◆ Plasma exchange Therapy: same as KTC-2000
◆ Na+and UF profiling:
Be applicable for reducing the cases during dialysis treatment such as low/high pressure, muscle convulsion, headache, nausea, vomit ect.
◆ Kt/V function:
   The sufficiency of dialysis can be reflected by Kt/V.(Standard)
◆ HCO3 adjustment function:
   Be applicable for serious acid toxicosis patient.
   Be capable to calibrate the acid toxicosis status according to patient's state of   illness(Standard)
◆ Backup power-supply:
   It can last for 15-30 minutes after power cut off.
◆ Pyrogen filter port:
   Completely filtrating the remained bacteria and endotoxin.(optional)
◆ Net connection:
   One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)

Submit a question to our support team.
  • * Your Name:
  • Country:
  • Telephone:
  • * Your E-Mail:
  • * Messages:
  •  
  •  
  •  
  • Certified By:
  • db  iso
  • Member Of:
  • jx  cccmhpie  global compact
  • Contact us
  • Export Dept: +86 791-86496032
    Int'l Bidding Dept: +86 791-88165662
    Import Dept: +86 791-86166316
    Project(China) Dept: +86 791-88117976
    E_mail: info@kantecare.com
    MSN : kantecare@hotmail.com
    SKYPE: kantecare
    Address: 7/F,Block A Zhejiang University Science Park, No.698 Jingdong Avenue, Nanchang, Jiangxi, P.R China

  • Follow Us: facebook  twitter  linkedin